On Sat, Apr 11, 2015 at 11:03 AM, Brandon Vincent
<[log in to unmask]> wrote:
> This is not correct. LSI SAS2008 I/O controllers do support TRIM with
> drives that support both deterministic trim (DRAT) and deterministic
> read zero after trim (DZAT).

My bad. I didn't see that this thread was about using the controller
in IR mode. Vladimir is correct about IR mode not supporting RAID.
Sorry for any confusion.