Subject: | |
From: | |
Reply To: | |
Date: | Sun, 8 Jan 2006 03:45:05 +0200 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Robert Boehm wrote:
> Agreed...you should get the data off of that disk NOW..
> do a SMART check...or test would be good too:
> #smartclt -t short /dev/<the device>
>
> then after the two to 10 minutes of the test:
>
> #smartctl -a /dev/<the device>
> and check out the specifics...
>
> WARNING: If the disk is VERY marginal..the test alone can cause it
> to fail...get that data off!!!
I did both the "long" and "short" tests. This is a bit long email, but I thought being
thorough. Its contents are:
(1) The log results of the tests.
(2) The summary lines of the tests.
(1) [root@localhost download]# smartctl -t long /dev/hdc
smartctl version 5.33 [i386-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Extended self-test routine immediately in off-li ne mode".
Drive command "Execute SMART Extended self-test routine immediately in off-line mode"
successful.
Testing has begun.
Please wait 35 minutes for test to complete.
Test will complete after Sun Jan 8 01:35:34 2006
Use smartctl -X to abort test.
[root@localhost download]# smartctl -a /dev/hdc
smartctl version 5.33 [i386-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: WDC WD800JB-00FMA0
Serial Number: WD-WCAJ92485805
Firmware Version: 13.03G13
User Capacity: 80,026,361,856 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 6
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Sun Jan 8 03:09:13 2006 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command f rom host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (2460) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off supp ort.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 35) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_ FAILED
RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0007 113 101 021 Pre-fail Always - 1683
4 Start_Stop_Count 0x0032 099 099 040 Old_age Always - 1891
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 200 200 051 Pre-fail Always - 0
9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 5906
10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
11 Calibration_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1872
194 Temperature_Celsius 0x0022 103 010 000 Old_age Always - 40
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0012 200 200 000 Old_age Always - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 142
200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA
_of_first_error
# 1 Extended offline Completed without error 00% 5904 -
# 2 Extended offline Completed without error 00% 4982 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
[root@localhost download]#
[root@localhost download]# smartctl -t short /dev/hdc
smartctl version 5.33 [i386-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line mode".
Drive command "Execute SMART Short self-test routine immediately in off-line mode" successful.
Testing has begun.
Please wait 2 minutes for test to complete.
Test will complete after Sun Jan 8 03:22:41 2006
Use smartctl -X to abort test.
[root@localhost download]# smartctl -a /dev/hdc
smartctl version 5.33 [i386-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: WDC WD800JB-00FMA0
Serial Number: WD-WCAJ92485805
Firmware Version: 13.03G13
User Capacity: 80,026,361,856 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 6
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Sun Jan 8 03:34:41 2006 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (2460) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 35) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED
RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0007 113 101 021 Pre-fail Always - 1683
4 Start_Stop_Count 0x0032 099 099 040 Old_age Always - 1891
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 200 200 051 Pre-fail Always - 0
9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 5906
10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
11 Calibration_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1872
194 Temperature_Celsius 0x0022 101 010 000 Old_age Always - 42
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0012 200 200 000 Old_age Always - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 142
200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error# 1 Short offline Completed without error 00% 5906
-
# 2 Extended offline Completed without error 00% 5904 -
# 3 Extended offline Completed without error 00% 4982 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
[root@localhost download]#
(2) I think the lines of:
Long test: "SMART overall-health self-assessment test result: PASSED"
Short test: "SMART overall-health self-assessment test result: PASSED"
mean it looks OK.
|
|
|